Skip to main content
Taishi® External Wall Insulation Board

TSH

Taishi® External Wall Insulation Board

Stone wool board for the insulation layer of thin-plastered external wall systems (ETICS).

Density (kg/m³)
140–160
Thickness, factory range (mm)
30–200
λ measured, W/(m·K)
0.034
Reaction to fire, EN 13501-1
A1

Grades

Models of this series by density grade
Model CodeDensity (kg/m³)Thickness, factory range (mm)Thickness, CE window (mm)DoPλ measured, W/(m·K)
TSH140
30–200
50–200
TAISHI-DoP-EN13162-140 Issued on request
0.034 WSW 25100049
TSH160
30–200
50–150
TAISHI-DoP-EN13162-160 Issued on request
0.034 WSW 25100050

Technical data

Technical data by model
PropertyTSH140TSH160Basis
Manufacturer's figures under Chinese standards
Tensile Strength kPa
≥10
≥15
Compressive Resistance (10%) kPa
≥40
≥40
Thermal Conductivity W/(m·K)
≤0.040
≤0.040
Hydrophobic Rate %
≥98
≥98
Acidity Coefficient
≥1.8
≥1.8
Moisture Absorption by Mass %
≤0.4
≤0.4
Short-term Water Absorption (24h) kg/m²
≤0.4
≤0.4
Long-term Water Absorption (28d) kg/m²
≤1.0
≤1.0
Dimensional Stability %
≤1.0
≤1.0
Thickness Deviation mm
±3
±3
Right Angle Deviation mm/m
≤5
≤5
Planeness mm
≤6
≤6
Melting Temperature °C
>1000
>1000
-
EN evidence
EN 12667 measured λ, 10 °C mean W/(m·K)
0.034 WSW 25100049 · 200 mm
0.034 WSW 25100050 · 30 mm
Reaction to fire
Reaction to fire, EN 13501-1
A1
A1
Combustion Class
A
A
GB 8624-2012, type test

EN 12667 values are measured, one report per density grade, each given with its report number and specimen thickness.

Rock wool vs glass wool: fire performance compared

Dimensions and cutting

Board sizes of this series
Size (mm)Models
1200×600
TSH140 and TSH160
Dimensional tolerances
Confirmed per order.

Other widths and lengths are cut to order.

Board weight and container load

Board weight and 40 ft high-cube load by model and thickness
Model CodeSize (mm)Thickness (mm)Weight per board (kg)Per 40 ft high-cube (m²)
TSH140 · 50 mmTSH140
1200×600
50
5.0
1,200
TSH140 · 100 mmTSH140
1200×600
100
10.1
600
TSH160 · 50 mmTSH160
1200×600
50
5.8
1,200
TSH160 · 100 mmTSH160
1200×600
100
11.5
600

Weights are at nominal density. Container areas are the factory's 60 m³ per 40 ft high-cube divided by the thickness. Each order's packing list states the actual count and weight.

Estimate container loads for these specs

Used in

Typical uses

  • Thin plastering external wall insulation system
  • Curtain wall insulation backing
  • Fire and waterproof wall assemblies

Documents

Documents for this series
DocumentTypeIssuedLanguageSizeStatusFile
Taishi® External Wall Insulation Board (TSH) datasheet
Datasheet
EN
117 KB
Public
CE Conformity (EN 13162) 2649-CPR-26000401
Certificate
2026-02-26
407 KB
Public
Declaration of Performance, 140 kg/m³ TAISHI-DoP-EN13162-140
Declaration of Performance
On request
Declaration of Performance, 160 kg/m³ TAISHI-DoP-EN13162-160
Declaration of Performance
On request
Test report ledger

Every test report behind the figures on this page, with laboratory, method and date.

Ordering

Minimum order
60 m³ per density grade, one 40 ft high-cube container for each grade
40 ft high-cube load
60 m³, about 1,200 m² of 50 mm board, the factory's figure
Production
3 to 5 days from receipt of the deposit, then the sailing is booked
Samples
3 boards of 500 × 500 mm per grade, on your courier account, ready in 2 to 3 business days
Price basis
FOB Qingdao as standard, CIF or CFR to your port on request
Payment
30% T/T deposit, 70% against a copy of the bill of lading, or an irrevocable L/C at sight
Quotation
First reply within 1 business day, formal quotation within 1 to 2 business days

Interested in this product?

Tell us your target specification, volume, and destination port. We'll respond with pricing, lead time, and documentation.