Skip to main content

Stone Wool for External Walls, Curtain Walls and Steel-Frame Walls

External wall board and vertical strip for ETICS render facades, and curtain wall board for the fire stop at each slab edge. Steel-frame walls take TSD board as cavity fill.

Typical build-up, ETICS render facade

  1. Masonry or concrete wall
  2. Adhesive mortar
  3. TSH board, bonded and anchored
  4. Reinforced base coat
  5. Finish render

TSS100 kg/m³

Taishi® Vertical Wall Insulation Strip

Stone wool strips with the fibres turned perpendicular to the face, for ETICS on high-rise and coastal buildings.

  • CE Conformity (EN 13162)100 kg/m³

TSM60–120 kg/m³

Taishi® Curtain Wall Insulation Board

Fine-fibre stone wool board for curtain wall cavities and the fire stop at the slab edge.

  • CE Conformity (EN 13162)60–120 kg/m³
  • GOST Fire Safety (Russia)120 kg/m³

TSD40–140 kg/m³

Taishi® Multipurpose Stone Wool Board

Fine-fibre stone wool board for partitions, ceilings and general building and industrial insulation.

  • CE Conformity (EN 13162)40–140 kg/m³
  • GOST Fire Safety (Russia)120 kg/m³

Steel-frame walls: 60 and 80 kg/m³

Grades for this element

Models for this element, with the CE window, DoP and measured λ of each grade
Model CodeDensity (kg/m³)Thickness, factory range (mm)Thickness, CE window (mm)DoPλ measured, W/(m·K)
Taishi® External Wall Insulation Board
TSH140
30–200
50–200
TAISHI-DoP-EN13162-140 Issued on request
0.034 WSW 25100049
TSH160
30–200
50–150
TAISHI-DoP-EN13162-160 Issued on request
0.034 WSW 25100050
Taishi® Vertical Wall Insulation Strip
TSS100
30–200
50–200
TAISHI-DoP-EN13162-100 Issued on request
0.031 WSW 25100045
Taishi® Curtain Wall Insulation Board
TSM60
30–100
50–200
0.032 WSW 25100053
TSM80
30–100
50–200
0.031 WSW 25100046
TSM100
30–100
50–200
TAISHI-DoP-EN13162-100 Issued on request
0.031 WSW 25100045
TSM120
30–100
50–200
TAISHI-DoP-EN13162-120 Issued on request
0.034 WSW 25100048
  • CE certificate 2649-CPR-26000401 covers 60, 80, 100, 120, and 140 kg/m³, at thicknesses within 50–200 mm.
  • CE certificate 2649-CPR-26000401 covers 160 kg/m³, at thicknesses within 50–150 mm.

Specifying and fitting

ETICS render facades

TSH board forms the insulation layer of an external thermal insulation composite system: bonded and anchored to the wall, then covered with a reinforced base coat and a finish render. The ETICS kit holder names the adhesive, anchors and render. Your engineer checks the build-up against local facade rules with the papers on this page.

Vertical strip on high-rise facades

TSS strip has its fibres turned perpendicular to the wall face, the format render systems call lamella. Buyers use it on high-rise and coastal facades.

Curtain wall fire stops

TSM board fills the curtain wall cavity and closes the gap between each floor slab and the curtain wall. The fire stop is a tested assembly from the curtain wall or fire-stopping supplier. Send its reference and the gap width with your inquiry, and we confirm the grade and thickness.

Rock Wool vs Glass Wool: Density & compressive strength

Steel-frame walls

Light gauge steel frame (LGSF) walls take stone wool board as cavity fill between the studs. Buyers ask for TSD60 and TSD80 here. Board width to suit the stud spacing is confirmed per order.

TSD grades for steel-frame cavity fill
Model CodeDensity (kg/m³)Thickness, factory range (mm)Thickness, CE window (mm)DoPλ measured, W/(m·K)
Taishi® Multipurpose Stone Wool Board
TSD60
30–200
50–200
0.032 WSW 25100053
TSD80
30–200
50–200
0.031 WSW 25100046
  • CE certificate 2649-CPR-26000401 covers 60 and 80 kg/m³, at thicknesses within 50–200 mm.

What this element needs

Standards this element is specified against
StandardWhat it coversDeclared and measured values
EN 13162:2012+A1:2015
Specifies requirements for factory made mineral wool products, with or without facings or coatings, for the thermal insulation of buildings. A harmonised standard under Regulation (EU) No 305/2011.
EN 13501-1:2018
Sets the reaction-to-fire classes of construction products from the results of the EN reaction-to-fire tests.
EN 12667:2001
Method for measuring thermal resistance and thermal conductivity with a guarded hot plate or a heat flow meter.
EN 1607:2013
Method for measuring the tensile strength of an insulation board perpendicular to its faces.
GB/T 25975-2018
Chinese product standard for rock wool used in external wall insulation systems.

Papers by market

Certificates held for this element, by market
MarketWe hold
European Union
  • CE Conformity (EN 13162) 2649-CPR-26000401
United Kingdom
  • CE Conformity (EN 13162) 2649-CPR-26000401
Israel
  • CE Conformity (EN 13162) 2649-CPR-26000401
Gulf: Saudi Arabia
  • CE Conformity (EN 13162) 2649-CPR-26000401
Russia and CIS
  • GOST Fire Safety (Russia) РОСС RU.32079.04СПБ1.ОС14.64027

Evidence

Test reports behind these grades
ReportLaboratoryMethodResultGrades
WSW 25100045–25100053
CTC Nanjing Guocai Testing Co., Ltd.
Thermal conductivity at 10 °C mean for each grade, measured on a single batch.
40, 60, 80, 100, 110, 120, 140, 160, and 180
XJ2026B03D02237
Conforms to GB/T 19686-2015 in full. Reaction to fire class A (A1) under GB 8624-2012.
80
WSW 25030179
Conforms to GB/T 19686-2015 in full. Reaction to fire class A (A1) under GB 8624-2012. Three-star green building material under T/CECS 10032-2019.
100
SHFS2401000125FF
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.
Reaction to fire class A1 under EN 13501-1:2018, with measured values for the other properties.
140
SHFS2401000126FF
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.
Reaction to fire class A1 under EN 13501-1:2018, with measured values for thermal conductivity and compressive stress.
80
251202026SHF-001
Intertek
Non-combustibility test data. Read it with the classification report for the same density.
40
251202026SHF-002
Intertek
Gross heat of combustion test data. Read it with the classification report for the same density.
40
251202026SHF-003
Intertek
Classified A1 under EN 13501-1:2018.
40
251202026SHF-004
Intertek
Non-combustibility test data. Read it with the classification report for the same density.
180
251202026SHF-005
Intertek
Gross heat of combustion test data. Read it with the classification report for the same density.
180
251202026SHF-006
Intertek
Classified A1 under EN 13501-1:2018.
180

All test reports, with laboratories and accreditation marks

Get Your Wall Stone Wool Quote

Tell us the element, the grade and the quantity. First reply within 1 business day, formal quotation within 1 to 2 business days.