Skip to main content

Marine Stone Wool Insulation

TSC board and TSCL strip for bulkheads, columns and composite panels in shipbuilding. The CCS works approval rates the boards non-combustible under FTP Code Part 1.

Typical build-up, insulated steel bulkhead

  1. Steel bulkhead
  2. TSC board
  3. Aluminium foil or glass fibre tissue facing
  4. Lining panel

TSC80–220 kg/m³

Taishi® Marine Insulation Stone Wool Board

Stone wool board for shipbuilding insulation in bulkheads, columns and marine composite panels.

  • CCS Works Approval80, 120, 150, 160, and 200 kg/m³
  • CE Conformity (EN 13162)80, 120, and 160 kg/m³
  • GOST Fire Safety (Russia)120 kg/m³

Grades for this element

Models for this element, with the CE window, DoP and measured λ of each grade
Model CodeDensity (kg/m³)Thickness, factory range (mm)Thickness, CE window (mm)DoPλ measured, W/(m·K)
Taishi® Marine Insulation Stone Wool Board
TSC80
30–150
50–200
0.031 WSW 25100046
TSC120
30–150
50–200
TAISHI-DoP-EN13162-120 Issued on request
0.034 WSW 25100048
TSC160
30–150
50–150
TAISHI-DoP-EN13162-160 Issued on request
0.034 WSW 25100050
TSC200
30–150
TSCL120
48.5–100
50–200
TAISHI-DoP-EN13162-120 Issued on request
0.034 WSW 25100048
TSCL150
48.5–100
TSCL200
23–100
TSCL220
23–100
  • CE certificate 2649-CPR-26000401 covers 80 and 120 kg/m³, at thicknesses within 50–200 mm.
  • CE certificate 2649-CPR-26000401 covers 160 kg/m³, at thicknesses within 50–150 mm.

Specifying and fitting

Bulkheads, columns and beams

Board fills bulkhead and partition cavities and wraps steel columns and beams, for thermal and acoustic separation between compartments.

Composite panel core

High-density board and lamella strip form the core of the composite panels used for ship walls, ceilings and interior linings.

Rock Wool vs Glass Wool: Water resistance & durability

What this element needs

Standards this element is specified against
StandardWhat it coversDeclared and measured values
IMO 2010 FTP Code
IMO fire test procedures for ships. Part 1 is the non-combustibility test behind the CCS works approval on file; A, B and F class divisions are tested as whole constructions under Part 3.

Papers by market

Certificates held for this element, by market
MarketWe hold
European Union
  • CE Conformity (EN 13162) 2649-CPR-26000401
United Kingdom
  • CE Conformity (EN 13162) 2649-CPR-26000401
Israel
  • CE Conformity (EN 13162) 2649-CPR-26000401
Gulf: Saudi Arabia
  • CE Conformity (EN 13162) 2649-CPR-26000401
Russia and CIS
  • GOST Fire Safety (Russia) РОСС RU.32079.04СПБ1.ОС14.64027

Evidence

Test reports behind these grades
ReportLaboratoryMethodResultGrades
WSW 25100045–25100053
CTC Nanjing Guocai Testing Co., Ltd.
Thermal conductivity at 10 °C mean for each grade, measured on a single batch.
40, 60, 80, 100, 110, 120, 140, 160, and 180
XJ2026B03D02237
Conforms to GB/T 19686-2015 in full. Reaction to fire class A (A1) under GB 8624-2012.
80
SHFS2401000126FF
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.
Reaction to fire class A1 under EN 13501-1:2018, with measured values for thermal conductivity and compressive stress.
80
251202026SHF-001
Intertek
Non-combustibility test data. Read it with the classification report for the same density.
40
251202026SHF-002
Intertek
Gross heat of combustion test data. Read it with the classification report for the same density.
40
251202026SHF-003
Intertek
Classified A1 under EN 13501-1:2018.
40
251202026SHF-004
Intertek
Non-combustibility test data. Read it with the classification report for the same density.
180
251202026SHF-005
Intertek
Gross heat of combustion test data. Read it with the classification report for the same density.
180
251202026SHF-006
Intertek
Classified A1 under EN 13501-1:2018.
180

All test reports, with laboratories and accreditation marks

Request Marine Quote

Tell us the element, the grade and the quantity. First reply within 1 business day, formal quotation within 1 to 2 business days.