Skip to main content

Density grades

12 density grades of stone wool board. For each one: the models, the thickness window on the CE certificate, the DoP, the measured thermal conductivity, the basis for reaction to fire and the papers held for each market.

Paper matrix

One row per grade. Each cell names a paper and links to it, or reads none.

  • Not on the CE certificate: 150, 200, and 220 kg/m³.
  • Not on the CE certificate: thicknesses under 50 mm.
  • Faced boards: the certificate is silent on facings, and no fire test exists on a faced board.

40 kg/m³

Models and thickness
  • TSW40 Taishi® Roof Insulation Board, factory thickness 30–200 mm
  • TSD40 Taishi® Multipurpose Stone Wool Board, factory thickness 30–200 mm

CE window: 50–200 mm.

Thermal conductivity

0.035 W/(m·K), measured under EN 12667:2001 on a 50 mm specimen.

CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.

Report WSW 25100052

Single-batch measured value, not a λ90/90 declared value.

Reaction to fire

Class A1 under EN 13501-1, on the CE certificate.

Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)

Reports at this density: 251202026SHF-001, 251202026SHF-002

Other EN properties

Not measured under EN methods.

Open items

None for this grade alone.

12 open items concern every grade

Request a quote for 40 kg/m³

60 kg/m³

Models and thickness
  • TSW60 Taishi® Roof Insulation Board, factory thickness 30–200 mm
  • TSM60 Taishi® Curtain Wall Insulation Board, factory thickness 30–100 mm
  • TSD60 Taishi® Multipurpose Stone Wool Board, factory thickness 30–200 mm

CE window: 50–200 mm.

Thermal conductivity

0.032 W/(m·K), measured under EN 12667:2001 on a 60 mm specimen.

CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.

Report WSW 25100053

Single-batch measured value, not a λ90/90 declared value.

Reaction to fire

Class A1 under EN 13501-1, on the CE certificate.

Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)

Other EN properties

Not measured under EN methods.

Open items

None for this grade alone.

12 open items concern every grade

Request a quote for 60 kg/m³

80 kg/m³

Models and thickness
  • TSW80 Taishi® Roof Insulation Board, factory thickness 30–200 mm
  • TSM80 Taishi® Curtain Wall Insulation Board, factory thickness 30–100 mm
  • TSX80 Taishi® Sandwich Panel Core Stone Wool, factory thickness 30–200 mm
  • TSD80 Taishi® Multipurpose Stone Wool Board, factory thickness 30–200 mm
  • TSC80 Taishi® Marine Insulation Stone Wool Board, factory thickness 30–150 mm
  • TSFB80 Taishi® Fireproof Black Stone Wool Board, factory thickness 100 mm

CE window: 50–200 mm.

Thermal conductivity

0.031 W/(m·K), measured under EN 12667:2001 on a 80 mm specimen.

CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.

Report WSW 25100046

Single-batch measured value, not a λ90/90 declared value.

Reaction to fire

Class A1 under EN 13501-1, on the CE certificate.

Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)

Reports at this density: XJ2026B03D02237, SHFS2401000126FF

Certificates: CCS Works Approval

Other EN properties
EN measurements at 80 kg/m³
PropertyValueMethodReport
Thermal conductivity λ0.0326 W/(m·K)EN 12667:2001SHFS2401000126FF
Thermal resistance R at specimen thickness1.53 m²·K/WEN 12667:2001SHFS2401000126FF
Compressive stress at 10 % deformation, CS(10)13.5 kPaEN ISO 29469:2022SHFS2401000126FF
Open items

None for this grade alone.

12 open items concern every grade

Request a quote for 80 kg/m³

100 kg/m³

Models and thickness
  • TSS100 Taishi® Vertical Wall Insulation Strip, factory thickness 30–200 mm
  • TSM100 Taishi® Curtain Wall Insulation Board, factory thickness 30–100 mm
  • TSX100 Taishi® Sandwich Panel Core Stone Wool, factory thickness 30–200 mm
  • TSF100 Taishi® Composite Slab Stone Wool Board, factory thickness 100 mm
  • TSD100 Taishi® Multipurpose Stone Wool Board, factory thickness 50–100 mm
  • TSFB110 Taishi® Fireproof Black Stone Wool Board, factory thickness 100 mm

CE window: 50–200 mm.

Thermal conductivity

0.031 W/(m·K), measured under EN 12667:2001 on a 100 mm specimen.

CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.

Report WSW 25100045

Single-batch measured value, not a λ90/90 declared value.

Reaction to fire

Class A1 under EN 13501-1, on the CE certificate.

Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)

Reports at this density: WSW 25030179

Other EN properties

Not measured under EN methods.

Open items

None for this grade alone.

12 open items concern every grade

Request a quote for 100 kg/m³

110 kg/m³

Models and thickness

CE-listed, not in catalogue

CE window: 50–200 mm.

Thermal conductivity

0.031 W/(m·K), measured under EN 12667:2001 on a 120 mm specimen.

CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.

Report WSW 25100047

Single-batch measured value, not a λ90/90 declared value.

Reaction to fire

Class A1 under EN 13501-1, on the CE certificate.

Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)

Other EN properties

Not measured under EN methods.

Open items

None for this grade alone.

12 open items concern every grade

Request a quote for 110 kg/m³

120 kg/m³

Models and thickness
  • TSM120 Taishi® Curtain Wall Insulation Board, factory thickness 30–100 mm
  • TSX120 Taishi® Sandwich Panel Core Stone Wool, factory thickness 30–200 mm
  • TSF120 Taishi® Composite Slab Stone Wool Board, factory thickness 100 mm
  • TSD120 Taishi® Multipurpose Stone Wool Board, factory thickness 50–100 mm
  • TSC120 Taishi® Marine Insulation Stone Wool Board, factory thickness 30–150 mm
  • TSCL120 Taishi® Marine Insulation Stone Wool Board, factory thickness 48.5–100 mm

CE window: 50–200 mm.

Thermal conductivity

0.034 W/(m·K), measured under EN 12667:2001 on a 150 mm specimen.

CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.

Report WSW 25100048

Single-batch measured value, not a λ90/90 declared value.

Reaction to fire

Class A1 under EN 13501-1, on the CE certificate.

Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)

Certificates: CCS Works Approval, GOST Fire Safety (Russia)

Other EN properties

Not measured under EN methods.

Open items

None for this grade alone.

12 open items concern every grade

Request a quote for 120 kg/m³

140 kg/m³

Models and thickness
  • TSH140 Taishi® External Wall Insulation Board, factory thickness 30–200 mm
  • TSX140 Taishi® Sandwich Panel Core Stone Wool, factory thickness 30–200 mm
  • TSD140 Taishi® Multipurpose Stone Wool Board, factory thickness 50–100 mm

CE window: 50–200 mm.

Thermal conductivity

0.034 W/(m·K), measured under EN 12667:2001 on a 200 mm specimen.

CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.

Report WSW 25100049

Single-batch measured value, not a λ90/90 declared value.

Reaction to fire

Class A1 under EN 13501-1, on the CE certificate.

Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)

Reports at this density: SHFS2401000125FF

Other EN properties
EN measurements at 140 kg/m³
PropertyValueMethodReport
Thermal conductivity λ0.0354 W/(m·K)EN 12667:2001SHFS2401000125FF
Thermal resistance R at specimen thickness2.30 m²·K/WEN 12667:2001SHFS2401000125FF
Compressive stress at 10 % deformation, CS(10)66.6 kPaEN ISO 29469:2022SHFS2401000125FF
Tensile strength perpendicular to faces, TR20.5 kPaEN 1607:2013SHFS2401000125FF
Short-term water absorption, WS0.09 kg/m²EN ISO 29767:2019SHFS2401000125FF
Long-term water absorption, WL(P)0.18 kg/m²EN ISO 16535:2019SHFS2401000125FF
Dimensional stability, length / width / thickness0.0 / 0.0 / 0.5 %EN 1604:2013SHFS2401000125FF
Open items

None for this grade alone.

12 open items concern every grade

Request a quote for 140 kg/m³

150 kg/m³

Models and thickness
  • TSCL150 Taishi® Marine Insulation Stone Wool Board, factory thickness 48.5–100 mm

Not on the CE certificate.

The factory can produce board at 150 kg/m³. No test report exists for it under any standard. Not held: Test reports for 150 kg/m³ board

Thermal conductivity

Not measured under EN 12667.

Reaction to fire

No EN 13501-1 class: the grade is not on the CE certificate.

Certificates: CCS Works Approval

Other EN properties

Not measured under EN methods.

Request a quote for 150 kg/m³

160 kg/m³

Models and thickness
  • TSH160 Taishi® External Wall Insulation Board, factory thickness 30–200 mm
  • TSC160 Taishi® Marine Insulation Stone Wool Board, factory thickness 30–150 mm

CE window: 50–150 mm.

Thermal conductivity

0.034 W/(m·K), measured under EN 12667:2001 on a 30 mm specimen.

CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.

Report WSW 25100050

Single-batch measured value, not a λ90/90 declared value.

Reaction to fire

Class A1 under EN 13501-1, on the CE certificate.

Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)

Certificates: CCS Works Approval

Other EN properties

Not measured under EN methods.

Open items

None for this grade alone.

12 open items concern every grade

Request a quote for 160 kg/m³

180 kg/m³

Models and thickness

CE-listed, not in catalogue

CE window: 50–100 mm.

Thermal conductivity

0.037 W/(m·K), measured under EN 12667:2001 on a 100 mm specimen.

CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.

Report WSW 25100051

Single-batch measured value, not a λ90/90 declared value.

Reaction to fire

Class A1 under EN 13501-1, on the CE certificate.

Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)

Reports at this density: 251202026SHF-004, 251202026SHF-005

Other EN properties

Not measured under EN methods.

Open items

None for this grade alone.

12 open items concern every grade

Request a quote for 180 kg/m³

200 kg/m³

Models and thickness
  • TSC200 Taishi® Marine Insulation Stone Wool Board, factory thickness 30–150 mm
  • TSCL200 Taishi® Marine Insulation Stone Wool Board, factory thickness 23–100 mm

Not on the CE certificate.

Thermal conductivity

Not measured under EN 12667.

Reaction to fire

No EN 13501-1 class: the grade is not on the CE certificate.

Certificates: CCS Works Approval

Other EN properties

Not measured under EN methods.

Open items

None for this grade alone.

12 open items concern every grade

Request a quote for 200 kg/m³

220 kg/m³

Models and thickness
  • TSCL220 Taishi® Marine Insulation Stone Wool Board, factory thickness 23–100 mm

Not on the CE certificate.

Thermal conductivity

Not measured under EN 12667.

Reaction to fire

No EN 13501-1 class: the grade is not on the CE certificate.

Other EN properties

Not measured under EN methods.

Open items

None for this grade alone.

12 open items concern every grade

Request a quote for 220 kg/m³

Grades not on the certificate

The CE certificate lists 9 grades from 40 to 180 kg/m³, the two densities its A1 classification reports were tested at. 150, 200, and 220 kg/m³ are not on its density table, so no DoP exists for them.

  • 150 kg/m³: made as TSCL150. The factory can produce board at 150 kg/m³. No test report exists for it under any standard. Not held: Test reports for 150 kg/m³ board
  • 200 kg/m³: made as TSC200 and TSCL200. Board at this density for other uses is confirmed per order.
  • 220 kg/m³: made as TSCL220. Board at this density for other uses is confirmed per order.

A density between two listed grades, such as 130 kg/m³, is not on the certificate either. The nearest grades on it are 120 and 140 kg/m³, and the manufacturer can apply to the notified body to add a grade.

Quote by density grade

Name the grade, the thickness and the quantity. We reply with the price and the papers for that grade.