Skip to main content

Industrial Stone Wool for Pipework, Ductwork and Process Equipment

TSCL strip, TSD board and TSC board for pipework, vessels, ductwork, air-handling units and plant rooms.

Typical build-up, vessel or tank wall

  1. Steel vessel or tank wall
  2. TSCL lamella strip, fibres perpendicular to the surface
  3. Metal cladding

TSC80–220 kg/m³

Taishi® Marine Insulation Stone Wool Board

Stone wool board for shipbuilding insulation in bulkheads, columns and marine composite panels.

  • CCS Works Approval80, 120, 150, 160, and 200 kg/m³
  • CE Conformity (EN 13162)80, 120, and 160 kg/m³
  • GOST Fire Safety (Russia)120 kg/m³

TSD40–140 kg/m³

Taishi® Multipurpose Stone Wool Board

Fine-fibre stone wool board for partitions, ceilings and general building and industrial insulation.

  • CE Conformity (EN 13162)40–140 kg/m³
  • GOST Fire Safety (Russia)120 kg/m³

Grades for this element

Models for this element, with the CE window, DoP and measured λ of each grade
Model CodeDensity (kg/m³)Thickness, factory range (mm)Thickness, CE window (mm)DoPλ measured, W/(m·K)
Taishi® Marine Insulation Stone Wool Board
TSC80
30–150
50–200
0.031 WSW 25100046
TSC120
30–150
50–200
TAISHI-DoP-EN13162-120 Issued on request
0.034 WSW 25100048
TSC160
30–150
50–150
TAISHI-DoP-EN13162-160 Issued on request
0.034 WSW 25100050
TSC200
30–150
TSCL120
48.5–100
50–200
TAISHI-DoP-EN13162-120 Issued on request
0.034 WSW 25100048
TSCL150
48.5–100
TSCL200
23–100
TSCL220
23–100
Taishi® Multipurpose Stone Wool Board
TSD40
30–200
50–200
TAISHI-DoP-EN13162-040 Issued on request
0.035 WSW 25100052
TSD60
30–200
50–200
0.032 WSW 25100053
TSD80
30–200
50–200
0.031 WSW 25100046
TSD100
50–100
50–200
TAISHI-DoP-EN13162-100 Issued on request
0.031 WSW 25100045
TSD120
50–100
50–200
TAISHI-DoP-EN13162-120 Issued on request
0.034 WSW 25100048
TSD140
50–100
50–200
TAISHI-DoP-EN13162-140 Issued on request
0.034 WSW 25100049
  • CE certificate 2649-CPR-26000401 covers 40, 60, 80, 100, 120, and 140 kg/m³, at thicknesses within 50–200 mm.
  • CE certificate 2649-CPR-26000401 covers 160 kg/m³, at thicknesses within 50–150 mm.

Specifying and fitting

Pipework, vessels and tanks

Lamella strip wraps large pipes, vessels and tanks with its fibres perpendicular to the surface. Your engineer sets the thickness from the heat-loss and surface-temperature targets at the operating temperature.

Ductwork and air-handling units

Board lines or wraps supply and return ducts, air-handling units and plenum walls for thermal and acoustic treatment. The mechanical engineer sets the thickness for the duct's heat-gain and noise targets.

Equipment housings and plant rooms

Board lines the housings of pumps, compressors and generators and the walls of plant rooms. TSD serves mixed sites where one board covers several uses.

Rock Wool vs Glass Wool: Max service temperature

What this element needs

Standards this element is specified against
StandardWhat it coversDeclared and measured values
EN 13162:2012+A1:2015
Specifies requirements for factory made mineral wool products, with or without facings or coatings, for the thermal insulation of buildings. A harmonised standard under Regulation (EU) No 305/2011.
EN 13501-1:2018
Sets the reaction-to-fire classes of construction products from the results of the EN reaction-to-fire tests.
EN 12667:2001
Method for measuring thermal resistance and thermal conductivity with a guarded hot plate or a heat flow meter.

Papers by market

Certificates held for this element, by market
MarketWe hold
European Union
  • CE Conformity (EN 13162) 2649-CPR-26000401
United Kingdom
  • CE Conformity (EN 13162) 2649-CPR-26000401
Israel
  • CE Conformity (EN 13162) 2649-CPR-26000401
Gulf: Saudi Arabia
  • CE Conformity (EN 13162) 2649-CPR-26000401
Russia and CIS
  • GOST Fire Safety (Russia) РОСС RU.32079.04СПБ1.ОС14.64027

Evidence

Test reports behind these grades
ReportLaboratoryMethodResultGrades
WSW 25100045–25100053
CTC Nanjing Guocai Testing Co., Ltd.
Thermal conductivity at 10 °C mean for each grade, measured on a single batch.
40, 60, 80, 100, 110, 120, 140, 160, and 180
XJ2026B03D02237
Conforms to GB/T 19686-2015 in full. Reaction to fire class A (A1) under GB 8624-2012.
80
WSW 25030179
Conforms to GB/T 19686-2015 in full. Reaction to fire class A (A1) under GB 8624-2012. Three-star green building material under T/CECS 10032-2019.
100
SHFS2401000125FF
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.
Reaction to fire class A1 under EN 13501-1:2018, with measured values for the other properties.
140
SHFS2401000126FF
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.
Reaction to fire class A1 under EN 13501-1:2018, with measured values for thermal conductivity and compressive stress.
80
251202026SHF-001
Intertek
Non-combustibility test data. Read it with the classification report for the same density.
40
251202026SHF-002
Intertek
Gross heat of combustion test data. Read it with the classification report for the same density.
40
251202026SHF-003
Intertek
Classified A1 under EN 13501-1:2018.
40
251202026SHF-004
Intertek
Non-combustibility test data. Read it with the classification report for the same density.
180
251202026SHF-005
Intertek
Gross heat of combustion test data. Read it with the classification report for the same density.
180
251202026SHF-006
Intertek
Classified A1 under EN 13501-1:2018.
180

All test reports, with laboratories and accreditation marks

Get Your Industrial Stone Wool Quote

Tell us the element, the grade and the quantity. First reply within 1 business day, formal quotation within 1 to 2 business days.